With your meter cabinet, a single-phase home battery fits on any connection, while a three-phase home battery only works if your meter cabinet has three phases. For most households, one phase is enough, even if there's three-phase power in the meter cabinet. Three phases only become interesting when you draw a lot of power at once or want to keep your entire home running on backup power.
In this blog you'll read how to recognize your connection, what happens when the battery and your consumption are on different phases, and how plug-in systems still let you use all three phases.
What is the difference between a single-phase and a three-phase home battery?
The difference between a single-phase and a three-phase home battery lies in the number of lines the battery uses to charge and deliver power. A single-phase battery uses one phase of your home's wiring, while a three-phase battery spreads charging and discharging across three phases at once. The storage capacity in kWh is separate from this: the difference is in the power, the connection you need and what keeps working during a power outage.
Every home battery for your home falls into one of these two groups. A single-phase home battery is easier to install, but its power is limited by the single phase it shares with the rest of the house. A three-phase home battery delivers more power, but requires a meter cabinet with three phases, a heavier inverter and always an installer. Your connection is therefore the first filter: start with your own meter cabinet and only then look at the power you need.
How can you tell whether you have a single-phase or three-phase connection?
You can tell whether you have a single-phase or three-phase connection by looking at three parts in your meter cabinet. You don't need to unscrew or disconnect anything, because everything is right there on the outside of the parts. Do check this before choosing a home battery, since your connection determines which systems are suitable for you. Pay attention to these three points:
- Main switch: a 2-pole main switch indicates single-phase, a 4-pole one indicates three-phase.
- Main fuse: a label like 1x25A or 1x35A means single-phase, 3x25A means three-phase.
- Smart meter: if the display or the rating plate shows only L1, you have one phase; if it shows L1, L2 and L3 or 3x230/400V, you have three phases.
Still in doubt? You can also find the connection rating for your address with your grid operator. Never work behind the main switch yourself, because that part of the meter cupboard is for a certified installer.
Can a 1-phase home battery run on a 3-phase connection?
Yes, a 1-phase home battery can run on a 3-phase connection. The battery then sits on one of the three phases and supplies its power to your home installation via that phase. This is the usual situation with home batteries you connect yourself, because the Zendure and Anker SOLIX home batteries at TechPunt are all 1-phase systems.
This works well thanks to two things: the way your smart meter settles the phases and the meter with which the battery keeps an eye on all phases.
The smart meter settles all phases together
The smart meter settles all phases together, so you don't lose any power if the home battery is on a different phase than your consumption. A Dutch smart meter adds the three phases together and only records the balance of your entire connection.
If the battery delivers 800 watts on phase 1 while the washing machine draws 800 watts on phase 2, the meter records nothing on balance. That's why you won't see counters per phase on the display either, but four registers: supply and feed-in, each at a high and a low rate.
A P1 meter or CT clamps measure all three phases
A P1 meter or CT clamps measure all three phases, so the battery knows how much power your home is drawing at that moment. A P1 meter reads out the smart meter and passes on the total of all phases, and for charging and discharging on the net balance that's enough.
CT clamps fit around the phase wires in the fuse box and measure each phase separately. For this there are the Zendure Smart Meter 3CT with three clamps and the Anker SOLIX Smart Meter Gen 2 in the three-phase version with the Triple CT cable assembly.
You'll find both meters among the accessories for your home battery. The meters are brand-specific, so pick the meter from the same brand as your battery. CT clamps go in the meter cupboard, so leave that to an installer.
Why does a home battery with a plug always run on one phase?
A home battery with a plug always runs on one phase, because every socket is on one circuit and every circuit is on one phase. A plug-in home battery that you plug into the socket yourself is therefore always a 1-phase system, even in a home with three phases. The power then depends on the circuit: a standard 16 amp circuit can handle around 3,680 watts, and you share that capacity with everything else connected to that circuit.
If you want to get more power out of a single unit, an electrician connects the battery to its own circuit. That delivers up to 3,500 watts with the Anker SOLIX Solarbank Max AC and up to 4,000 watts with the Zendure SolarFlow 4000 Mix series. Even then, it remains a 1-phase system. You can read how to go about this in the blog on connecting a home battery.
When do you need a 3-phase home battery?
You need a 3-phase home battery in two situations: when one phase doesn't provide enough power for what your home demands at the same time, or when you want to keep the entire home running during a power outage. For storing solar power for the evening, one phase is more than enough for most households.
When you draw a lot of power at once through a heat pump, charging station or induction
When you draw a lot of power at once through a heat pump, charging station or induction cooktop, you need a 3-phase home battery, because one phase then becomes too tight. A 1x25 amp connection delivers around 5.7 kilowatts in total, and 1x35 amps about 8 kilowatts. A 3x25 amp connection reaches over 17 kilowatts, spread across three phases.
If those devices are running at the same time, you'll quickly hit the limit on one phase, especially when the battery is charging on that same phase. The same happens with a dynamic energy contract: the more power the battery has, the more electricity it stores during the cheapest hours.
For backup power for the entire home
For backup power for the whole home, you need a three-phase system on a three-phase connection, because only a system that feeds all three phases keeps the entire meter cabinet running. During a power outage, a battery only supplies power to what is physically connected to its backup power supply. A single single-phase battery on three phases then at most covers the devices on its own backup power output.
On a single-phase connection it's different. There, one battery with an automatic switch can take over the whole house, like the Anker SOLIX Solarbank Max AC with the Backup Auto-Switch. That switch is only suitable for homes with a single phase. You can see which models have a backup power function at the home batteries with backup power.
How do you build a three-phase home battery with plug-in systems?
You build a three-phase home battery with plug-in systems by distributing multiple single-phase units across the three phases. There are two routes for that:
- Separate units per phase: you place two or three batteries of the same brand on different phases and have them controlled by a meter that sees all the phases, provided the system supports multiple units.
- Zendure PowerHub 3P: this central hub links three SolarFlow Mix units, one per phase, into a single system of up to 12 kilowatts continuous and keeps all three phases running during a power outage.
Both setups require an installer, because work is done in the meter cabinet and the load across the phases has to stay balanced. A home battery of 0.8 kilowatts or more also needs to be registered with your grid operator. You can read what that involves in the blog about registering a home battery.
Choose a home battery that fits your connection
If you have a single phase, you choose a single-phase home battery and you're all set. If you have three phases, you usually also start with one unit and a meter that sees all the phases. Later you expand to multiple units or a PowerHub 3P, as soon as you need more power or full backup power.